Logistics & Warehousing

Logistics Warehouse — Jacksonville, FL

180,000 sq ft facility
22% energy reduction
14 months ROI
Large modern warehouse facility with loading docks

The Challenge

A major logistics company was facing escalating energy costs at their 180,000 sq ft distribution center. With 24/7 operations and energy-intensive material handling equipment, utility bills had become a significant operational expense. The facility was also experiencing frequent lighting outages that were affecting productivity and safety.

Our Approach

  • Comprehensive ASHRAE Level II audit - Detailed analysis of all energy systems
  • Utility rate analysis - Identified suboptimal tariff structure
  • Operational assessment - Studied material handling patterns and schedules
  • Equipment performance evaluation - Analyzed HVAC and lighting systems
  • Financial modeling - Prioritized measures by ROI and payback

Implemented Solutions

LED + Controls Upgrade

Replaced 450 high-bay fixtures with LED and occupancy sensors, reducing lighting energy by 65%

HVAC Optimization

Adjusted temperature setpoints and schedules, installed VFDs on air handling units

Utility Rate Switch

Negotiated favorable time-of-use rate reducing demand charges by 18%

Compressed Air System

Right-sized compressors and fixed leaks, reducing pneumatic system energy by 30%

Results

22% reduction in total energy consumption
$78,000 annual energy cost savings
14 months simple payback period
95% reduction in lighting maintenance issues
Education

K–12 School District — Southeast US

12 school buildings
9% district-wide savings
$120k annual savings
Modern school building exterior with students

The Challenge

A growing school district needed to reduce operating costs while maintaining comfortable learning environments. With aging buildings and outdated energy systems, the district was spending over $1.3 million annually on energy costs. Budget constraints made it essential to find low-cost, high-impact solutions that wouldn't disrupt educational activities.

Our Approach

  • District-wide energy assessment - Benchmarked all 12 buildings using ENERGY STAR
  • Operational schedule analysis - Identified energy waste during unoccupied hours
  • Student and staff engagement - Developed energy awareness programs
  • Low-cost/no-cost optimization - Focused on operational improvements first
  • Rebate procurement - Secured utility incentives for equipment upgrades

Implemented Solutions

Schedule Optimization

Aligned HVAC and lighting schedules with actual occupancy patterns, reducing energy during holidays and breaks

Plug Load Management

Implemented smart power strips and energy awareness programs in classrooms and offices

Daylighting Controls

Installed daylight sensors in classrooms with southern exposure, reducing artificial lighting needs

Retro-commissioning

Optimized existing HVAC controls and fixed calibration issues across the district

Results

9% reduction in district-wide energy use
$120,000 annual cost savings
500 MWh annual energy savings
750+ students engaged in energy education
Multi-Family Real Estate

Multi‑Family Community — Florida

350 kW solar installation
32% common-area reduction
18 months ROI
Modern apartment complex with amenities

The Challenge

A 450-unit luxury apartment community wanted to reduce common-area electricity costs while preparing for the growing electric vehicle adoption among residents. The property management team needed solutions that would enhance property value and tenant satisfaction while delivering measurable cost savings for competitive advantage in the market.

Our Approach

  • Solar feasibility analysis - Assessed rooftop and parking canopy potential
  • EV infrastructure planning - Designed scalable charging solution
  • Utility optimization - Analyzed rate structures and demand patterns
  • Financial modeling - Compared solar ownership vs. PPA options
  • Resident engagement strategy - Sustainability communications plan

Implemented Solutions

Rooftop Solar System

350 kW solar installation on clubhouse and amenity buildings with 25-year performance warranty

Smart Utility Management

Advanced demand response controls for pool equipment and HVAC systems

EV Charging Network

12 Level 2 charging stations with smart load management and resident billing integration

LED Common Area Upgrade

Complete lighting retrofit with motion sensors and astronomical time clocks

Results

450 MWh annual solar production
32% reduction in common-area electricity costs
$52,000 annual utility savings
85% resident satisfaction with EV amenities

Ready to achieve similar results?

Every organization has unique energy challenges and opportunities. Let's explore what's possible for your facility.